Skip to content

RJ45 Pinout Color Code: T568A vs T568B Ethernet Wiring Chart

Tech Vivek Hardaha

Advertisement
RJ45 Pinout – RJ45 Wiring Colours

Making or repairing an Ethernet cable raises one question again and again: what is the correct RJ45 wire order? There are two recognised answers, T568A and T568B, and they differ only by swapping the orange and green pairs. This guide explains how to read the pin numbers, gives both colour orders side by side, clarifies how Cat5e, Cat6 and Cat6A relate to them, and shows simple ways to test a finished cable. It covers low-voltage data cabling only. It has nothing to do with mains (household electricity) wiring and must not be used for that.

RJ45 pin numbering and orientation

An RJ45 plug has eight gold contacts. To number them correctly, hold the plug with the plastic clip tab facing down and the contacts facing you. Pin 1 is on the left and pin 8 on the right. Several manufacturers, including Monoprice, describe the same orientation.

Reading the plug from the correct side

Holding the plug the wrong way round reverses the whole sequence, which is the most common cause of a wrong cable. When you insert wires before crimping, picture them in this same view: tab down, pin 1 at the left.

Eight-pin RJ45 Ethernet connector wiring colours for T568A and T568B
RJ45 T568A and T568B Wiring Colour Code

T568A versus T568B color order

PinT568AT568B
1White/GreenWhite/Orange
2GreenOrange
3White/OrangeWhite/Green
4BlueBlue
5White/BlueWhite/Blue
6OrangeGreen
7White/BrownWhite/Brown
8BrownBrown

Orientation: clip tab down, contacts facing you, pin 1 on the left. “White/Green” means the white wire with a green stripe (or white-and-green striped wire), the partner of the solid green wire.

Pair identification and side-by-side diagram

An Ethernet cable holds four twisted pairs: blue, orange, green and brown. Each pair is a solid-colour wire plus its striped white partner. Keep each pair together: both wires of a colour belong to the same twisted pair, even when their pins are not next to each other (the green or orange pair in this scheme straddles pins 3 and 6). Putting wires from different pairs on a pin pair is called a split pair, and it can pass a simple continuity test yet cause slow or unreliable networking.

  • Both schemes are defined by the TIA/EIA-568 standard and both work equally well electrically. Consistency matters more than which one you pick.
  • A straight-through cable uses the same scheme on both ends (A to A, or B to B).
  • Different schemes on the two ends produce a crossover-type cable, which is rarely needed with modern equipment because ports detect the connection automatically.
  • T568B is widely used in commercial installations, while some specifications, including certain government projects, call for T568A. Follow the scheme of your existing wiring or project specification.

Cat5e, Cat6 and Cat6A compatibility

Cat5e, Cat6 and Cat6A are cable categories. All of them are terminated with the same T568A or T568B colour order. The category does not change the wire order; it describes the cable’s construction and performance.

Cable category versus termination pattern

CategoryTypical useNotes
Cat5eHome and small office, up to Gigabit (1 Gbps)Common and low-cost
Cat6Gigabit, faster over short runsRated to 250 MHz
Cat6A10 Gigabit over the full 100 mRated to 500 MHz; thicker cable

According to Monoprice’s guide, Cat6A supports 10 Gigabit Ethernet at the full 100 m and operates up to 500 MHz, compared with 250 MHz for Cat6. Real speed also depends on your switch, router, network card and cable quality. Older 10/100 Mbps links use only pins 1, 2, 3 and 6, while Gigabit uses all eight wires, which is why a fault on one pair can leave an old-speed link working but break Gigabit.

How to check Ethernet cable faults

An inexpensive cable tester plugs into both ends and lights numbered LEDs 1 to 8 in order. For a straight-through cable, the same sequence should appear on both units.

Tester interpretation and common mistakes

  • An LED is skipped: that wire is broken or not touching its contact. Re-terminate the plug.
  • The order is jumbled: wires are in the wrong pins. Compare with the table above.
  • All lights pass but the link is slow: suspect a split pair or damaged cable, which a simple continuity test does not catch.
  • Too much untwisting: keep the pairs twisted as close to the plug as possible, since excessive untwisting hurts performance.

Worked examples, practical checks and limitations

Illustrative example: you need a 20 m cable between a router and a room. Choose T568B for both ends. With the clip down, left to right: white/orange, orange, white/green, blue, white/blue, green, white/brown, brown. After crimping, attach a tester and confirm that LEDs 1 to 8 light in the same order at both ends.

  • This chart is for low-voltage data cabling only; it has no use in mains wiring.
  • Twisted-pair Ethernet runs are generally limited to about 100 m before a switch or repeater is needed.
  • Follow any T568A or T568B labels on existing wall jacks and patch panels.
  • Different connector brands may differ slightly in how the wires are loaded; read the maker’s guide.

Common mistakes and when to seek expert confirmation

  • Reading the sequence with the clip facing up, which reverses it.
  • Using T568A on one end and T568B on the other when a straight cable is intended.
  • Choosing the partner wire only by colour rather than keeping each twisted pair together.
  • Using poor connectors or no proper crimping tool.

For in-wall cabling, patch-panel work or certified speed requirements, use a qualified network installer.

Frequently asked questions

What is the correct RJ45 wire order?

For T568B, pins 1 to 8 are white/orange, orange, white/green, blue, white/blue, green, white/brown, brown. T568A swaps the green and orange pairs. Read with the clip down and pin 1 on the left.

What is the difference between T568A and T568B?

Only the orange and green pairs are swapped. Both are valid; use one consistently across the whole network.

Do Cat5e, Cat6 and Cat6A use different colour codes?

No. They all use the same T568A or T568B order. The categories differ in cable performance, not in wire order.

Can I use T568A on one end and T568B on the other?

Not for an ordinary straight cable. Mixed ends make a crossover-style cable, which modern equipment rarely needs.

How long can an Ethernet cable be?

Generally up to about 100 m for twisted-pair Ethernet. Beyond that you need extra network equipment.

Conclusion

You do not need to memorise the sequence: remember the orientation (clip down, pin 1 on the left), keep to one scheme, and verify the finished cable with a tester. For permanent or certified installations, bring in a qualified installer.

Sources

Free tools for Tech

View all →

Share Your Opinion

Comments are closed on this post.

More on Site